<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>KWJ Engineering &#187; Mining</title>
	<atom:link href="http://www.kwjengineering.com/products/tag/mining/feed" rel="self" type="application/rss+xml" />
	<link>http://www.kwjengineering.com</link>
	<description>Just another WordPress weblog</description>
	<lastBuildDate>Mon, 20 Sep 2010 21:55:39 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.1</generator>
		<item>
		<title>A345</title>
		<link>http://www.kwjengineering.com/products/methanenatural-gaspropane/fixed-instruments-for-methanenatural-gaspropane/a345</link>
		<comments>http://www.kwjengineering.com/products/methanenatural-gaspropane/fixed-instruments-for-methanenatural-gaspropane/a345#comments</comments>
		<pubDate>Tue, 11 Mar 2008 03:06:16 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Company News]]></category>
		<category><![CDATA[Bio Gas Analysis]]></category>
		<category><![CDATA[Bio-remediation]]></category>
		<category><![CDATA[Greenhouse Gases]]></category>
		<category><![CDATA[Industrial Waste Management]]></category>
		<category><![CDATA[Landfill Management / Environmental Services]]></category>
		<category><![CDATA[Mining]]></category>
		<category><![CDATA[Sewage Treatment]]></category>
		<category><![CDATA[Waste Management]]></category>

		<guid isPermaLink="false">http://www.kwjengineering.com/products/methanenatural-gaspropane/fixed-instruments-for-methanenatural-gaspropane/a345</guid>
		<description><![CDATA[The KWJ 345 BIOGAS â€˜FiveElevationsâ€™ Landfill MonitorÂ  is a BIOGAS detection system for CO2 in a range of 0-60% and CH4 in a range of 0-60% measured through five different elevations in a well or sample site.Â  This unique system utilizes solenoid valves to separate gas samples drawn at each inlet, each equipped with flow [...]]]></description>
			<content:encoded><![CDATA[<p>The KWJ 345 BIOGAS â€˜FiveElevationsâ€™ Landfill MonitorÂ  is a BIOGAS detection system for CO2 in a range of 0-60% and CH4 in a range of 0-60% measured through five different elevations in a well or sample site.Â  This unique system utilizes solenoid valves to separate gas samples drawn at each inlet, each equipped with flow failure alarms.Â  Outputs are converted to a 4-20mA transmission to local or remote data logger and are time modulated so logged data can be interpreted in terms of sample line number or depth of sample point. Contact us to request full specifications and pricing. </p>
]]></content:encoded>
			<wfw:commentRss>http://www.kwjengineering.com/products/methanenatural-gaspropane/fixed-instruments-for-methanenatural-gaspropane/a345/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>A409</title>
		<link>http://www.kwjengineering.com/products/carbon-monoxide/inline/a409</link>
		<comments>http://www.kwjengineering.com/products/carbon-monoxide/inline/a409#comments</comments>
		<pubDate>Sun, 09 Mar 2008 06:21:59 +0000</pubDate>
		<dc:creator>Dave Abouav</dc:creator>
				<category><![CDATA[Company News]]></category>
		<category><![CDATA[Air Quality]]></category>
		<category><![CDATA[Breathing Air Quality]]></category>
		<category><![CDATA[Engine Fume Protection]]></category>
		<category><![CDATA[Marine Commercial Vessels]]></category>
		<category><![CDATA[Mining]]></category>
		<category><![CDATA[Oil/Gas Industry]]></category>
		<category><![CDATA[Parking Garages]]></category>

		<guid isPermaLink="false">http://www.kwjengineering.com/products/carbon-monoxide/inline/a409</guid>
		<description><![CDATA[The KWJ 409 Compressed Air CO Monitor is a rugged, compact (5â€ x 4â€ x 2.5â€) and weatherproof DC powered gas detector that continuously monitors a compressed air sample and alarms at a preset point in the range 0-200ppm CO.]]></description>
			<content:encoded><![CDATA[<p>The KWJ 409 Compressed Air CO Monitor is a rugged, compact (5â€ x 4â€ x 2.5â€) and weatherproof DC powered gas detector that continuously monitors a compressed air sample and alarms at a preset point in the range 0-200ppm CO. </p>
]]></content:encoded>
			<wfw:commentRss>http://www.kwjengineering.com/products/carbon-monoxide/inline/a409/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>A222</title>
		<link>http://www.kwjengineering.com/products/carbon-monoxide/portable/a222</link>
		<comments>http://www.kwjengineering.com/products/carbon-monoxide/portable/a222#comments</comments>
		<pubDate>Sun, 09 Mar 2008 06:00:42 +0000</pubDate>
		<dc:creator>Dave Abouav</dc:creator>
				<category><![CDATA[Company News]]></category>
		<category><![CDATA[Air Quality]]></category>
		<category><![CDATA[Breathing Air Quality]]></category>
		<category><![CDATA[Industrial Waste Management]]></category>
		<category><![CDATA[Mining]]></category>
		<category><![CDATA[Oil/Gas Industry]]></category>

		<guid isPermaLink="false">http://www.kwjengineering.com/products/carbon-monoxide/portable/a222</guid>
		<description><![CDATA[The Model A-222 CO monitor is produced for Marco Blastmaster in a weather resistant Pelican case that can be placed or hung at the job site and connected to AC or DC power supply. While continuously monitoring a compressed air sample connected to its sample inlet, the A-222 gives an alarm when CO in the [...]]]></description>
			<content:encoded><![CDATA[<p>The Model A-222 CO monitor is produced for Marco Blastmaster in a weather resistant Pelican case that can be placed or hung at the job site and connected to AC or DC power supply.  While continuously monitoring a compressed air sample connected to its sample inlet, the A-222 gives an alarm when CO in the sample exceeds a preset level (adjustable) or there is a discontinuity in the detector circuit.    Compact and portable with sample flow regulator and a stable and superior electrochemical sensor, the A-222 is guaranteed to provide years of rugged service life under demanding industrial conditions. </p>
]]></content:encoded>
			<wfw:commentRss>http://www.kwjengineering.com/products/carbon-monoxide/portable/a222/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>A345</title>
		<link>http://www.kwjengineering.com/products/carbon-dioxide/fixed/a345</link>
		<comments>http://www.kwjengineering.com/products/carbon-dioxide/fixed/a345#comments</comments>
		<pubDate>Fri, 08 Feb 2008 02:23:47 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Company News]]></category>
		<category><![CDATA[Bio Gas Analysis]]></category>
		<category><![CDATA[Bio-remediation]]></category>
		<category><![CDATA[Greenhouse Gases]]></category>
		<category><![CDATA[Industrial Waste Management]]></category>
		<category><![CDATA[Landfill Management / Environmental Services]]></category>
		<category><![CDATA[Mining]]></category>
		<category><![CDATA[Sewage Treatment]]></category>
		<category><![CDATA[Waste Management]]></category>

		<guid isPermaLink="false">http://www.kwjengineering.com/products/carbon-dioxide/fixed/a345</guid>
		<description><![CDATA[The KWJ 345 BIOGAS â€˜FiveElevationsâ€™ Landfill MonitorÂ  is a BIOGAS detection system for CO2 in a range of 0-60% and CH4 in a range of 0-60% measured through five different elevations in a well or sample site.Â  This unique system utilizes solenoid valves to separate gas samples drawn at each inlet, each equipped with flow [...]]]></description>
			<content:encoded><![CDATA[<p>The <strong>KWJ 345 BIOGAS â€˜FiveElevationsâ€™ Landfill Monitor</strong>Â  is a BIOGAS detection system for CO2 in a range of 0-60% and CH4 in a range of 0-60% measured through five different elevations in a well or sample site.Â  This unique system utilizes solenoid valves to separate gas samples drawn at each inlet, each equipped with flow failure alarms.Â  Outputs are converted to a 4-20mA transmission to local or remote data logger and are time modulated so logged data can be interpreted in terms of sample line number or depth of sample point. </p>
]]></content:encoded>
			<wfw:commentRss>http://www.kwjengineering.com/products/carbon-dioxide/fixed/a345/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

