The KWJ 345 BIOGAS ‘FiveElevations’ Landfill Monitor is a BIOGAS detection system for CO2 in a range of 0-60% and CH4 in a range of 0-60% measured through five different elevations in a well or sample site. This unique system utilizes solenoid valves to separate gas samples drawn at each inlet, each equipped with flow failure alarms. Outputs are converted to a 4-20mA transmission to local or remote data logger and are time modulated so logged data can be interpreted in terms of sample line number or depth of sample point.
This product was a custom solution for a KWJ customer